The following messages are specific to the Communications Manager on NetWare.
An error occurred during a memory allocation operation. Free memory by unloading NLMs or reconfiguring NLMs to use less memory. Retry the operation. If the error persists, contact Technical Support at Pervasive Software.
An internal error occurred during a semaphore allocation operation. Retry the operation. If the error persists, contact Technical Support at Pervasive Software.
Ensure that BSPXCOM's version is compatible with the version number of the workstation's MKDE Requester.
To solve this condition, unload all other NLMs. Load BTRIEVE.NLM and NWBSRVCM.NLM, and then reload the other NLMs. This process reveals the NLM that is using BSPXCOM.NLM's socket number.
An error occurred during an SPX-level receive operation. Refer to your operating system documentation for the definition of the error number. Retry the operation. If the error persists, contact Technical Support at Pervasive Software.
An error occurred during an SPX-level send operation. Refer to your operating system documentation for the definition of the error number. Retry the operation. If the error persists, contact Technical Support at Pervasive Software.
If this message appears frequently, increase your requester's SPX Timeout parameter, which is controlled with the configuration properties. Also, check for NLMs that are monopolizing the CPU time.
If this message appears frequently, increase your requester's SPX Timeout parameter, which is controlled with the configuration properties. Also, check for NLMs that are monopolizing the CPU time.
An error occurred during an SPX-level session establishment operation. Refer to your operating system documentation for the definition of the error number value. Retry the operation. If the error persists, contact Technical Support at Pervasive Software.
Obsolete in Pervasive.SQL 8 and later versions.
Increase the value specified for the Number of Remote Sessions in the configuration properties.
Ensure that your BSPXCOM.NLM version is compatible with the version number of the Monitor utility.
Ensure that the version of BSPXCOM.NLM is compatible with the version number of the Monitor utility.
An error occurred during BSPXCOM.NLM thread initialization. Refer to the Pervasive Software Event Log (PVSW.LOG) for error messages preceding this one. Correct the problem and retry the operation.
An error occurred during a BeginThread operation. Refer to your operating system documentation for the definition of the error number value. Retry the operation. If the error persists, contact Technical Support at Pervasive Software.
|
Chapter contents