1 to 199
Show this topic in Library frames
MicroKernel Database Engine Status Codes
This section describes status codes that the MicroKernel returns.
1: The operation parameter is invalid
The specified operation does not exist or is not valid.
You may receive this error if you are running a general-release version of the V8 client software against a pre-release version of the V8 database engine. If this is the case, you must uninstall your database engine and install the general release version.
2: The application encountered an I/O error
This status code typically indicates a corrupt file, an error while reading from or writing to the disk. One of the following has occurred:
- The file is damaged, and you must recover it. Refer to the Advanced Operations Guide for more information on recovering files.
- In NetWare, at least one MicroKernel data file is flagged as Shareable. All MicroKernel data files should be flagged as Non-Shareable. The MicroKernel is the only user that accesses the files (on behalf of many database users). As the only user, the MicroKernel can control the integrity of the data files. If you flag your MicroKernel data files as Shareable, data corruption can occur.
- For pre-v6.0 data files, there is a large pre-image file inside a transaction, and there is not enough disk space for a write to the pre-image file.
- For pre-v6.0 data files, there is one pre-image file for multiple data files. For example, if you name the data files CUSTOMER.ONE and CUSTOMER.TWO, both files have pre-image files named CUSTOMER.PRE.
- For pre-v6.0 data files that are larger than 768 MB, there is a conflict among locking mechanisms. The file has not been corrupted. Your application can retry the operation until the conflict is resolved (when the competing application releases the lock your application requires).
- A pre-v6.0 Btrieve engine attempted to open a v6.x or later MicroKernel file.
- With Btrieve for Windows NT Server Edition v6.15.445, 32 bit Windows application may return Status 2 or "MKDE Terminated with Service Specific Error 0" after running an application for an extended period of time.
- There was a conflict with the assignment of token handles and permissions. You may receive status 2 or corruption on very busy SMP boxes, when a user is deleted from the Btrieve Monitor and the user immediately reopens the files. There is an FTF for Pervasive.SQL v.7.0 Windows NT and for Service Pack 3 for Pervasive.SQL 2000i Windows NT. This issue has been fixed in Pervasive.SQL V8 and later releases.
Note
Please see our Pervasive.SQL Knowledge Base for new and updated articles on troubleshooting this status code. You can access the Knowledge Base at: http://support.pervasive.com/eSupport/.
3: The file is not open
The operation cannot execute because the file is not open. The application must perform a successful Open operation before the MicroKernel can process any other operations. The MicroKernel also returns this status code if the application passed an invalid position block for the file, or if the application passed a position block with a client ID other than the client ID used to open the file.
Note
Please see our Pervasive.SQL Knowledge Base for new and updated articles on troubleshooting this status code. You can access the Knowledge Base at: http://support.pervasive.com/eSupport/.
4: The application cannot find the key value
The MicroKernel cannot find the specified key value in the index path.
- When you receive this status code on an Update or Delete operation, it usually means that the file is damaged, and you must recreate it. Occasionally, a corrupt key can cause this status code. Drop the key, then add it again.
- The MicroKernel returns this status code when an application performs a Get Equal operation to search on field type char. It is caused by a mismatch of two fields at the char level. To resolve, fill the KeyBuffer with the same fill char type as the field.
5: The record has a key field containing a duplicate key value
The MicroKernel cannot add or update a record because the record has a key field that contains a duplicate key value for an index that does not allow duplicate values. The MicroKernel also returns this status code when it cannot create an index that does not allow duplicate key values because a duplicate key value already exists.
6: The key number parameter is invalid
The value stored in the key number parameter is not valid for the file being accessed. The key number must correspond to one of the keys defined for the file. Valid key numbers are 0 through 118.
7: The key number has changed
The key number parameter changed before a Get Next, Get Next Extended, Get Previous, or Get Previous Extended operation. The operation requires the same key number parameter as the previous operation, because the MicroKernel uses positioning information relative to the previous key number.
In a related situation, the MicroKernel returns this status code when an application performs a Delete or Update operation immediately following a Get operation. If the application changes the value of the key number in the Delete or Update operation (from the value used with the preceding Get operation), the MicroKernel deletes or updates the record as requested and does not return this status code, at least not at this point. However, the MicroKernel does return this status code on the very first Get Next, Get Next Extended, Get Previous, or Get Previous Extended operation performed after the deletion or update, even if that Get operation uses the same key value the application passed to the Delete or Update operation.
If you need to change key numbers between consecutive Get Next, Get Next Extended, Get Previous, or Get Previous Extended operations (or in Delete or Update operations as described in the preceding paragraph), use a Get Position operation followed by a Get Direct/Record operation to reestablish positioning for the new index path.
8: The current positioning is invalid
You must establish the current position in order to update or delete a record. Perform a Get or Step operation to establish the current position. The MicroKernel also returns this status code if the application passed an invalid position block for the file.
9: The operation encountered the end-of-file
The MicroKernel returns this status code in the following situations:
- The operation encountered an end-of-file boundary or tried to read past a file boundary (end-of-file or start-of-file).
- In a Get Next Extended, Get Previous Extended, Step Next Extended, or Step Previous Extended operation, the number of records satisfying the filtering condition is less than the number of specified records to be returned, and the reject count or filter limit has not been reached.
- When reading a file in ascending order according to an index path, the MicroKernel has already returned the last record in that index path. When reading a file in descending order according to an index path, the MicroKernel has already returned the first record in the index path.
- When using the Get By Percentage operation, either the value supplied for the percentage is too high-it exceeds 10,000 decimal (0x2710)-or the file contains no records.
- When using the Get operation using ActiveX Data Control, this error will occur only after the application is compiled and deployed. This error will not occur at design time during development. The error results from a missing MSDADC.DLL on the deployment machine. Make sure to include this file (MSDADC.DLL) in your installation script. This file is a Microsoft MDAC (Microsoft Data Access Component) file.
Note
Please see our Pervasive.SQL Knowledge Base for new and updated articles on Btrieve ActiveX Controls. You can access the Knowledge Base at: http://support.pervasive.com/eSupport/.
10: The key field is not modifiable
During an Update operation, the application attempted to modify a key field that cannot be modified by definition.
11: The specified filename is invalid
The MicroKernel returns this status code in the following situations:
- The specified filename does not conform to file naming conventions or the pathname is invalid. Make sure the filename or pathname is valid for the environment.
- If operating in the client/server environment:
- The application attempted to open a file that has .^^^ as its extension. This extension is reserved for the MicroKernel to use during continuous operation. (Only server engines can use continuous operation.)
- The data buffer for a Begin or End continuous operation is not set up correctly.
- You attempted to load a remote file when your client configuration settings for Local MicroKernel Engine and Use Remote MicroKernel Engine are incorrectly set to On and Off, respectively. To resolve this condition, at the client workstation, open Pervasive.SQL Control Center (see Starting PCC in Pervasive.SQL User's Guide). Under the Access properties category for MicroKernel Router, set Use Remote MicroKernel Engine to "On" (click the option). See To access configuration settings in PCC for a local client in Advanced Operations Guide.
- You attempted to open a local file with a Workgroup engine that isn't the designated Gateway engine for the file. Go to the directory where the file you attempted to open resides. Check to see if the
~pvsw~.loc in that directory is flagged read only. If it is, change it to read-write.
- If you are using the dynamic locator file with your Workgroup engine:
- Make sure the name of the second-level locator file specified in your first-level locator file does not have the same name as an existing directory. Also, make sure they are all on the same drive.
- Make sure the second-level locator file specified in your first-level locator file can be accessed by the engine.
- Make sure all the Workgroup engines sharing the dynamic locator feature have the exact same drive mapping to the server location where the data files reside.
- If you are accessing files on a DOS client:
- A NET START FULL for the Windows for Workgroups workstation was not used when it was booted into DOS. Use a NET START FULL to get a full redirector in the DOS client mode. BREQNT.EXE requires a full redirection. At the DOS prompt type "net ver" <Enter>. Here is the list of required components for a DOS workstation to connect to a Windows server:
LSL.COM LAN Card Driver
IPXODI.COM
IFSHLP.SYS
NET START FULL
These can be loaded high, using emm386. NET START FULL will load in upper memory. NETX is required ONLY if you are connecting to a NetWare server.
- You attempted to open a file with a long filename on NSS volumes. The MicroKernel queries the volumes using OS calls and then loads the appropriate drivers for the associated name spaces it find for the volumes. In this case, the MicroKernel was being loaded before mounting the volumes so it did not find the requirement for long filename support by the NSS volumes.
- Issue the MGRstart or Bstart command after loading the volumes. An example would be:
LOAD NSS
MOUNT ALL
SYS:ETC\INITSYS.NCF
MGRSTART or BSTART
- Embedded spaces configuration setting is "on." "On" is the default starting with Pervasive.SQL 9. Change the setting to "off" if your applications do not allow embedded spaces in file names.
- If you are working in the Microsoft Terminal Server environment:
- Approximately 5 users can work in a Windows application on 2 different Terminal Servers that are connected to a primary Windows server. If you have attempted to run on top of this limit, you will receive status codes 11 and 35. For the recovery solution for this instance, refer to Microsoft Knowledgebase Article 190162, "Terminal Server and the 2048 Open File Limitation."
12: The MicroKernel cannot find the specified file
- Check that the file exists and that you specified the correct file.
- Check the key buffer parameter to make sure the pathname is terminated with a blank or a binary zero.
- When accessing a file on a server, ensure that you have FILE SCAN rights to the directory in which the file resides. Occasionally, a corrupt key can cause this status code. Drop the key, then add it again.
- In Novell NetWare 4.x environments, check for files with the hidden file attribute at the Operating System level and remove the hidden file attribute.
This does not occur with NetWare 5.
- An ODBC connection may receive this code on NetWare 4.x with the Pervasive.SQL Workgroup Engine. This status code did not appear until Pervasive.SQL 2000 Service Pack 2a. It is caused by Netware 4.x reporting long directory in a different format than NetWare 3.x, NetWare 5.x, or the Win32 Environment.
Novell has a fix for this problem in a file named Mixmod6.exe. Search for file at Novell's web site (http://www.novell.com).
- This error code may also be returned when the file DBNames.CFG has been removed (for example, by the Pervasive.SQL cleanup utility) and old Data Source Names (DSNs) which reference that file are not removed from the ODBC configuration. You attempted to open a local file with a Workgroup engine that isn't the designated Gateway engine for the file. Go to the directory where the file you attempted to open resides. Check to see if the
~pvsw~.loc in that directory is flagged read only. If it is, change it to read-write.
- You may have a Status 12 returned and see X$FILE.DDF for the file name in your DDFs.
- If the file.ddf is examined with a Btrieve utility, the location name for the dictionary files will be x$file.ddf, x$field.ddf, x$index.ddf, instead of the standard file.ddf, field.ddf, index.ddf. An unsupported DDF Creation utility called DDL Services (DDLSVCS.DLL) created the DDFs. DDL Services has a known bug that causes the system table to be populated with incorrect data. .
- You may get Status 12 when a file with a filename or path with embedded spaces is opened on Windows 98/ME or on certain Windows 32-bit platfomrs. For long NetWare file names, support is available only in the MicroKernel and not in NLM utilities such as BUTIL.NLM. Btrieve data files can be accessed using long names but long names cannot be used for other files. For example, in the NLM command:
BUTIL -CREATE <outputFile> <descriptionFile>
Since MKDE manipulates the <outputFile> Btrieve data file, it can have a long name. However, the <descriptionFile> can only have a short name (such as BUTIL.NLM) since it does not accept long names. The solution is to enable the client configuration option, Application characteristics4Embedded Spaces.
To Enable Embedded Spaces in Pervasive.SQL 2000i or later:
- Start Pervasive.SQL Control Center (see Starting PCC in Pervasive.SQL User's Guide).
- Expand the nodes for Pervasive.SQL (click the plus (+) sign).
- Expand the Local Client node.
- Right-click on MicroKernel Router then click Properties. Login if prompted.
- Click Application Characteristics in the Properties tree.
- Click Embedded Spaces (a check mark indicates that the option is enabled).
13: The MicroKernel could not open the extension file for an extended file
The MicroKernel could not open the extension file for an extended file that the application tried to open. An extended file can consist of a base file and up to 31 extension files. Extension files must remain in the same volume and directory as their base files. The MicroKernel returns this status code if you delete, move, or rename the extension files.
14: The MicroKernel cannot create or open the pre-image file
The MicroKernel uses pre-image files only for pre-v6.0 data files.
The MicroKernel returns this status code in one of the following situations:
- The MicroKernel cannot create a new pre-image file because the disk directory is full. The MicroKernel must be able to create a pre-image file.
- The MicroKernel cannot open the pre-image file to restore file integrity. If the pre-image file is erased or damaged, the MicroKernel cannot restore the file integrity. Refer to Advanced Operations Guide for more information about recovering damaged files.
- The workstation MicroKernel cannot assign a handle to the pre-image file because the MicroKernel was not started by a user with access rights to the pre-image file.
- The file structure of a pre-image file created by this MicroKernel is different from the file structure of a pre-image file created by a v5.x MicroKernel. If you have an extraneous .PRE file in v5.x format, the MicroKernel returns this status code when you try to open the data file to which the .PRE file belongs.
15: The application encountered an I/O error during pre-imaging
The MicroKernel uses pre-image files only for pre-v6.0 data files.
- The pre-image file is damaged and the integrity of the data file cannot be ensured. Refer to Advanced Operations Guide for more information about recovering damaged files.
- The disk is full. Erase any unnecessary files.
16: The application encountered an expansion error
This status code is obsolete in MicroKernel versions 6.0 and later.
The MicroKernel encountered an error while writing the directory structure to disk prior to creating the expanded file partition. Either the MicroKernel cannot close the file, or a new page was added to the file and the MicroKernel cannot close and reopen the file to update the directory structure. Check for a disk hardware failure.
18: The disk is full
The MicroKernel can return this status code in the following situations:
- The disk is full and the MicroKernel cannot expand the file to accommodate additional records. Erase any unnecessary files.
- There is not enough space to append a new page to the data file.
- The pre-image file is out of disk space. If your files are in pre-v6.0 format and you are in a transaction, the pre-image file size increases for the duration of the transaction. If you receive this status code, either reduce the number of operations in the transaction, or obtain more disk space.
- For files located on a NetWare server, the NetWare owner name for the file is no longer valid, and your application tried to insert or update records in the file, thus causing the file to expand. In this case, the MicroKernel returns this status code when it needs to add a page to the file, regardless of how much disk space is available. To check for an owner name, use the NetWare utility NDIR. To add an owner name, use either FILER (a NetWare text utility) or the NetWare Administrator graphical utility.
- In some environments, you can restrict the amount of disk space available to each user. This status code indicates that the application attempted to expand a data file beyond the amount of disk space allocated to the file owner.
- You tried to read or modify a file which was not closed properly after a disk full error. Make sure that every application using the file at the time of the disk full error closed the file successfully.
- If a client connected to a Pervasive.SQL server encounters this status code, other clients performing read-only operations from the same disk may also receive a non-zero status.
19: The application encountered an unrecoverable error
To ensure file integrity, recover the file as described in Pervasive.SQL User's Guide.
20: The MicroKernel or Btrieve Requester is inactive
Note
For an expanded list of possible recovery solutions, consult the Pervasive.SQL Knowledge Base at http://support.pervasive.com/eSupport.
- If you are running an application in a client/server environment:
- Make sure the Btrieve requester is loaded.
- Verify that the IPX/SPX or TCP/IP protocol is properly installed at the client machine and that no two machines on the network have the same Internal Network Number.
- Make sure at least one of the client configuration options, Access4Use Local MicroKernel Engine or Access4Use Remote MicroKernel Engine is enabled. If your environment includes both a server engine and Workgroup engines, you should have both settings enabled.
- If you are running an application in a workstation/workgroup environment, make sure the MicroKernel is loaded.
- If you are running an application in a client/server environment and also need to access files located on a local drive:
- Make sure the Btrieve Requester is loaded.
- Make sure both of the client configuration options, Access4Use Local MicroKernel Engine or Access4Use Remote MicroKernel Engine are enabled.
- Make sure a local MicroKernel is available and loaded.
- If you are operating in a DOS server environment:
Pervasive.SQL 9 SP1 (9.1) installs BTRBOX95 by default. As long as this is installed no other requester can be used.
- If you want to use BREQNT, BREQUEST, or BREQTCP, you must remove BTRBOX95 and make sure the proper requesters are loaded. Refer to Getting Started with Pervasive.SQL for more information.
- If you want to use BTRBOX95:
- Change directories to
\pvsw\clients\dos\windosbox and run the setup utility. This loads the appropriate file for clients running Windows 98/ME or Windows 32-bit operating system. The setup program creates and places a README.TXT file in the \pvsw\W32DOXBOX directory.
- After installation, reboot the client.
- For Windows 32-bit platform users: open a command prompt and run a DOS Btrieve application.
- For Windows 98/ME users:
- Run the BTRBOX95.exe. A minimized dialog box appears, indicating that BTRBOX95 support is active. If you close this dialog box, it will unload BTRBOX95. You only need to run BTRBOX95.exe once even though you have multiple DOS sessions open.
- Open a command prompt and run your DOS Btrieve application.
- If you are operating in a NetWare environment:
- Make sure the Microkernel and (if applicable) the Btrieve Requester are loaded before generating any requests.
- Make sure the appropriate communication modules are loaded at the server.
- If you are operating in a Windows server environment:
- Make sure the MicroKernel is started before generating any requests.
- Make sure the Windows DLLs are in your path.
- Make sure the appropriate communications modules are loaded at the server.
21: The key buffer parameter is too short
The key buffer parameter is not long enough to accommodate the key field for the requested index path. Verify that the length of the key buffer equals the defined length of the key specified in the key number parameter.
22: The data buffer parameter is too short
- The data buffer parameter specified by the application was not large enough to accommodate either the minimum length of the record for an Insert or Update operation, or the entire record length for a Get or Step operation. Also, the data buffer may not be large enough to accommodate the length of data required for operations such as Create, Create Index, Stat, Get By Percentage, Find Percentage, or Version.
- For Get or Step operations, the MicroKernel returns as much data as it can and this status code, indicating that it cannot return the entire record.
- For an Insert operation, the MicroKernel does not insert the record if the data buffer is shorter than the fixed-length portion of the record.
- For an Update operation, if the data buffer is too short to contain the fixed-length portion of a record, the MicroKernel does not update the record.
- For the Create, Stat, and Create Index operations, the data buffer is not long enough to contain all the file specifications, the key specifications, and (if specified) the Alternate Collating Sequence (ACS) definition.
- For the Get by Percentage or Find Percentage operation, the data buffer length is less than 4 bytes.
- For the Version operation, the data buffer length is less than 5 bytes.
- The data buffer parameter is too short when access table with more than 60 field using ActiveX. Download the latest ActiveX controls from the Pervasive web site (http://www.pervasive.com/developerzone/access_methods/activex.asp)
- A corrupt file may be indicated if the file allows variable-length records and you receive this status code on a Get or Step operation. In such a corrupt file, you can receive Status Code 54 when you use Get or Step operations to read other records. Recover the file according to the instructions in Pervasive.SQL User's Guide.
23: The position block parameter is not 128 bytes long
This status code is obsolete in Btrieve language interface versions 6.0 and later.
The position block parameter must be exactly 128 bytes long.
24: The page size or data buffer size is invalid
The MicroKernel returns this status code in one of the following situations:
- The page size you specified when creating a file is invalid. The page size must be a multiple of 512 bytes and cannot exceed 4096 bytes (up to 8.x file format) or 8192 bytes (9.x and higher file formats).
- During a Create operation, the page size is the first file specification the MicroKernel checks. If you receive this status code at this point, it can indicate an invalid data buffer parameter.
25: The application cannot create the specified file
The MicroKernel returns this status code in one of the following situations:
- If an application attempted to create a data file, the disk directory or the disk itself may be full.
- If an application tried to create a file over an existing file, the existing file is open or the operating system will not allow the operation for another reason (such as when a file is flagged transactional in NetWare).
- In an attempt to create a Btrieve file over existing Btrieve file, this status will be returned. The keybuffer on the Btrieve create operation API (opcode 14) is set properly to create a file over an existing file.
One solution is to disable the Antivirus software. Contact the third party vendor for additional information on configuring the Antivirus software to eliminate scanning specific data files.
26: The number of keys specified is invalid
The number of keys specified for the page size is invalid. The number of key segments must be within the following limits:
Table 1-6 Maximum Number of Key Segments
|
Page Size
|
512
|
1024
|
1536
|
2048
|
2560
|
3072
|
3584
|
4096
|
|
Maximum Number Key Segments
|
8
|
23
|
24
|
54
|
54
|
54
|
54
|
119
|
If the MicroKernel is configured to create files in v5.x format, the maximum number of key segments is 8 for files using 512 byte page sizes; the maximum number of key segments for all other v5.x files is 24.
For a key-only file, this status code is also returned if the number of keys specified is not one, or the available linked keys is not zero (only one key is allowed for a key-only file.)
Pervasive.SQL 9 SP1 (9.1) nullable columns: Because each indexed nullable column with true null support requires an index consisting of 2 segments, you cannot have more than 59 indexed nullable columns in a table (or indexed nullable true null fields in a Btrieve file). This limit is smaller for smaller page sizes (1/2 the values noted above, rounded down). Any file created with Pervasive.SQL, with file create mode set to 7.x or later, and TRUENULLCREATE set to the default value of On, has true null support. Files created using an earlier file format, or with Pervasive.SQL 7, or with TRUENULLCREATE set to Off, do not have true null support and do not have this limitation.
27: The key position is invalid
The specified key field position is less than 1 or exceeds the defined record length for the file. Either the key position is greater than the record length or the key position plus the key length exceeds the record length.
28: The record length is invalid
The physical record length, which is the logical record length specified when creating the file plus any additional overhead for duplicate keys, reserved duplicate pointers, variable record pointers, and blank trunctation information must be less than or equal to the page size minus 10 bytes (8 bytes if creating files in version 5 file format), and must be greater than or equal to 4 bytes.
For key-only files, the maximum record length is 253 bytes (255 bytes if creating files in version 5 file format).
For more information about calculating the physical record length, see Pervasive.SQL Programmer's Guide.
29: The key length is invalid
The MicroKernel returns this status code in one of the following situations:
- You have not specified a key length that is greater than 0 but does not exceed 255 bytes. The length of a key segment must agree with its key type if the key type implies a length (for example, an integer key must have a length evenly divisible by two). Each key page in the file must be large enough to hold at least eight keys. If the page size is too small to accommodate eight occurrences of the specified key length (plus overhead), you must increase the file page size or decrease the key length.
- An additional byte of storage space is needed for the null indicator for the column. This error occurs through a SQL CREATE INDEX statement, or through the creation of a SQL PRIMARY KEY or FOREIGN KEY, if the index, or key, references a null CHAR column of 255 characters (or VARCHAR of 254). This additional byte causes the actual length of the index to be one byte longer, or 256 bytes. To resolve the error, reduce the size of the column or create the column as NOT NULL and try again. For a foreign key, if you decrease the size of the column, you must decrease both the referencing column and the referenced column.
- You have tried to create a Btrieve file with more than one index. This may occur in the Btrieve v6.15 Windows95/NT environment. The problem is reproducible developing 32-bit application using Microsoft Visual Basic and is caused by long variables aligned on even word boundaries. The solution is to not use the long variable in the KeySpec type. Use a four (4) byte string instead of a long variable in the type definition. Then convert the string into a long.
30: The file specified is not a MicroKernel file
This status code is returned in one of the following situations:
- The MicroKernel did not create the file, or a pre-v3.x MicroKernel created it.
- While using an earlier version of Btrieve, you opened a file created by a later version that has a format incompatible with the earlier version.
- The first page of the file may be damaged. Use a backup copy of your data file. If you receive this status code and you suspect that the header page of the source file is damaged, recover the file as described in Advanced Operations Guide.
- You have attempted to access a valid Btrieve file. This status code is returned when old engines access newer file formats. A likely scenario is that data created by a new server engine is later used by an earlier Workgroup engine. Status 30 can be reported if the file format is newer than the MicroKernel engine attempting to open it. Particularly, accessing a 7.x file with a 6.x engine causes this error.
NOTE: Previously, accessing a 6.x file with a 5.x engine returned Status 2: "the application encountered an I/O error".
31: The file is already extended
This status code is obsolete in MicroKernel versions 6.0 and later.
An application tried to extend a file that had already been extended; you can only extend a file once.
32: The file cannot be extended
The MicroKernel must create an extension file to accommodate a file which is growing larger than the operating system file size limit. However the MicroKernel encounters an error from the operating system when it tries to create and open the new extension file. Possible causes for receiving this status code include the following: the directory is full, the disk is full, or the MicroKernel has not been granted sufficient rights by the operating system.
33: The MicroKernel cannot unload
In the DOS environment, The MicroKernel returns this status code for the following reasons:
- You attempted to unload the MicroKernel when you have loaded another terminate and stay resident (TSR) program after you loaded the MicroKernel. Unload the other TSR before unloading the MicroKernel.
- You attempted to unload the MicroKernel from a 32-bit application that uses the BSTUB interface with the DOS/4G extender.
34: The specified extension name is invalid
This status code is obsolete in MicroKernel versions 6.0 and later.
An application specified an invalid filename for the extended partition. Check the validity of the filename.
35: The application encountered a directory error
Either a Get Directory operation specified a drive that does not exist, or a Set Directory operation specified an invalid pathname. Check the validity of both the drive and the pathname.
37: Another transaction is active
The application issued a Begin Transaction (19 or 1019) operation while another transaction was active by the same user or task; the active transaction can be nested or non-nested. This status code often indicates a problem in nested transactions within your application.
38: The MicroKernel encountered a transaction control file I/O error
This status code is obsolete in MicroKernel versions 7.0 and later.
The MicroKernel tried to write to the transaction control file. Possible causes for receiving this status code are that the disk is full, the disk is write protected, the transaction control file (BTRIEVE.TRN) that is created when you load the MicroKernel has been deleted, or the transaction control file is flagged read-only or is corrupt.
39: A Begin Transaction operation must precede an End/Abort Transaction operation
The application issued an End Transaction (20),or Abort Transaction (21) operation without a corresponding Begin Transaction (19 or 1019) operation. Make sure that each End or Abort Transaction operation in your program is executed only after a successful Begin Transaction operation.
40: The file access request exceeds the maximum number of files allowed
This status code is obsolete in MicroKernel versions 6.0 and later.
The application tried to access more than the maximum number of files allowed within a transaction. You set the maximum number of different files that you can access during a logical transaction when you configure the MicroKernel.
41: The MicroKernel does not allow the attempted operation
The application tried to perform an operation that is not allowed under these operating conditions. For example:
- The application attempts to perform a Step operation on a key-only file.
- If using a server engine, the key number parameter of a continuous operation MicroKernel call is not valid.
- The MicroKernel prohibits certain operations during transactions because they have too great an effect on the file or on performance. These operations include Set Owner, Clear Owner, Create Index, and Drop Index.
- An application running on a 9.x or higher engine attempts to create a format file prior to 6.x (0600).
42: A file previously opened in Accelerated mode was not closed
This status code is obsolete in MicroKernel versions 6.0 and later.
The MicroKernel returns this status code for the following reasons:
- Either the application tried to open a v5.x data file that was previously accessed in Accelerated mode by a v5.x MicroKernel and never successfully closed, or the application tried to open a file for which a v6.0 or later MicroKernel encountered an unrecoverable error during a Set or Clear Owner operation. The file integrity cannot be ensured. Refer to Advanced Operations Guide for information about recovering damaged files.
- Your application tried to open a file in MicroKernel v5.x format using a v5.x MicroKernel; however, that same file was previously accessed by a v6.0 or later MicroKernel, which failed to close the file successfully and left a pre-image file on the disk. Version 5.x MicroKernels cannot read pre-image files created in v6.0 or later format.
43: The specified record address is invalid
The MicroKernel returns this status code for the following reasons:
- The record address specified for a Get Direct operation is invalid. Either the address is outside the file boundaries, or it is not on a record boundary within or on a data page, or the record at the specified address has been deleted. For a Get Direct operation, specify the 4-byte address obtained by a Get Position operation.
- If the records' file is in v5.x format, this status code can indicate a file access conflict. For example, task 1 has a file locked in an exclusive transaction. Task 2 is reading records from the same file and tries to update a record that the transaction inserted. If task 2 reads the record and then task 1 aborts the transaction, task 2 receives this status code when issuing the Update operation.
- For a Find Percentage operation that is seeking a percentage based on a record's physical location within the file, the specified record address is invalid.
- The file may be corrupt, and you must recover it. Refer to Advanced Operations Guide for information about recovering damaged files.
44: The specified key path is invalid
The application tried to use the Get Direct/Record operation to establish positioning on an index path for a key whose value is null in the corresponding record. The MicroKernel cannot establish positioning based on a null key value.
45: The specified key flags are invalid
The key flags specification on a Create operation is inconsistent. If a key has multiple segments, the duplicate, modifiable, and null attributes should be the same for each segment in the key. Also, you cannot use the null or manual key attributes in a key-only file. The MicroKernel also returns this status code if the application attempted to specify a different Alternate Collating Sequence (ACS) for two or more segments of a segmented key.
46: Access to the requested file is denied
The MicroKernel returns this status code for the following reasons:
- The application opened a file in Read-only mode and tried to perform a Write operation on that file.
- The application attempted to perform a Write operation on a file that is flagged read-only by the operating system.
- When the application opened the file, it did not correctly specify the owner name required for updates.
- (Workgroup engine only) If a Workgroup engine user or task opens a file that a client machine has opened using a server MicroKernel, the MicroKernel returns this status code if the Workgroup engine user attempts to write to the file.
- (9.x and higher engines only) The application attempted to perform a Write operation on a 5.x format file. When using a 9.x or higher engine, you cannot perform a write operation such as insert or delete on a 5.x format file.
47: The number of files opened exceeds the maximum allowed
This status code is obsolete in MicroKernel versions 6.0 and later.
Pre-v6.0 workstation MicroKernels return this status code when the number of files opened in Accelerated mode exceeded the number of buffers available in the MicroKernel cache. When a file is opened in Accelerated mode, the MicroKernel reserves one of its cache buffers for the file. It always reserves five empty buffers for index manipulation. Reconfigure Btrieve with both a smaller /P configuration option (to allocate more buffers) and a larger /M option (to increase the cache allocation).
48: The alternate collating sequence definition is invalid
The MicroKernel returns this status code for the following reasons:
- The first byte of an Alternate Collating Sequence (ACS) definition (the identification byte) does not contain the hexadecimal value AC (for user-defined ACSs), AD (for locale-specific ACSs), or AE (for international sorting rules support). Make sure that the first byte contains the appropriate value.
- You set the Create File Version option to v5.x, and you attempted to create a file that contains a key with a locale-specific ACS. Pre-v6.0 files do not support locale-specific ACSs.
49: The extended key type is invalid
The MicroKernel returns this status code for the following reasons:
- You tried to create a file or an index with an invalid extended key type.
- You tried to assign an Alternate Collating Sequence (ACS) to a BINARY key or key segment. You can assign an ACS only to a STRING, LSTRING, WSTRING, WZSTRING, or ZSTRING key type.
- You defined an index requiring an ACS, but no ACS definition exists either in the file or in the key definition passed in the data buffer.
- You attempted to create a key segment with both the Case Insensitivity and the ACS flags set, and the MicroKernel is configured to create files in v5.x format. This combination is invalid for v5.x files.
- You set the Create File Version value to v5.x, and you attempted to create a file with a NUMERICSA or NUMERICSTS key. Pre-v6.x files do not support these key types.
OR
- You set the Create File Version value to v6.x, and you attempted to use one of the new Pervasive.SQL V7 data types, such as CURRENCY or TIMESTAMP. Pre-v7.x files do not support these key types. Increase the setting for this component.
To change the Create File Version setting:
- Start Pervasive.SQL Control Center (see Starting PCC in Pervasive.SQL User's Guide).
- Expand Engines and find the desired engine name.
- Right-click on the engine name and click Properties.
- Click Compatibility.
- In the right hand frame, adjust the Create File Version.
50: The file owner is already set
The application tried to perform a Set Owner operation on a file that already has an owner. Use the Clear Owner operation to remove the previous owner before specifying a new one.
51: The owner name is invalid
The MicroKernel returns this status code for the following reasons:
- If the application received this status code from a Set Owner operation, the owner names specified in the key buffer and data buffer do not match.
- If this status code occurred during an Open operation or a DROP TABLE statement, the application attempted to open a file that has an owner name assigned to it. The application must specify the correct owner name in the data buffer. Ensure that the owner name is null-terminated in the data buffer and that the data buffer length is set long enough to include the owner name plus the null terminator.
52: An error occurred while writing to the cache
This status code is obsolete in MicroKernel versions 6.0 and later.
While trying to make a cache buffer available, the MicroKernel attempted to write data to a disk from a file that was previously opened in Accelerated mode. The operating system returned an I/O error during the write. This generally indicates a hardware memory problem. Unload and reload Btrieve before you continue.
53: The language interface version is invalid
An application tried to access a file containing variable-length records with a language interface from Btrieve v3.15 or earlier.
54: The variable-length portion of the record is corrupt
During a Get or Step operation, the MicroKernel could not read all or part of the variable-length portion of a record. The MicroKernel returns as much data as possible to the application. This status code usually indicates that one or more pages used to store variable-length records are corrupt. Check the data buffer length the MicroKernel returns to see how much of the record was returned. Recover the damaged file as described in Pervasive.SQL User's Guide.
55: The application specified an invalid attribute for an AUTOINCREMENT key
The data field indexed by an AUTOINCREMENT key can be part of a different segmented key only if the key number of the AUTOINCREMENT key is less than the key number of the new segmented key and the new data type flag referencing the field is not AUTOINCREMENT
56: An index is incomplete
An index can be damaged if a Create Index operation (31) or a Drop Index operation (32) is interrupted before it runs to completion. Perform a Drop Index operation to completely remove the damaged index from the file, then rebuild the index with the Create Index operation, if desired.
57: An expanded memory error occurred
This status code is obsolete in MicroKernel versions 6.0 and later.
Btrieve for DOS returns this status code if it receives an error from the Expanded Memory Manager. This status code usually means that the MicroKernel was unable to save or restore the memory mapping register context, indicating an incompatibility with another application that uses expanded memory.
58: The compression buffer length is too short
This status code is obsolete in Pervasive.SQL 2000i and later versions.
59: The specified file already exists
During a Create operation, the application specified -1 in the key number parameter and the name of an existing file in the key buffer parameter. To overwrite the existing file, remove the -1 from the key number parameter. To preserve the existing file, alter the filename specified in the key buffer parameter.
60: The specified reject count has been reached
The MicroKernel rejected the number of records specified by the reject count before a Get Next Extended, Get Previous Extended, Step Next Extended, or Step Previous Extended operation found the requested number of records that satisfy the filtering condition. Check the first two bytes returned in the data buffer for the number of records that were retrieved.
61: The work space is too small
The Get Next Extended, Get Previous Extended, Step Next Extended, and Step Previous Extended operations use a buffer as work space. This status code indicates that the work space (set by default to 16 KB) is not large enough to hold the filtering data buffer structure and the largest record to be received. You will receive Status Code 0 if the work space is large enough to hold the filter/extraction expression and enough of the record to include all of the fields to be filtered or extracted.
62: The descriptor is incorrect
This status code is returned in the following situations:
- The descriptor (data buffer structure), which is passed for a Get Next Extended, Get Previous Extended, Step Next Extended, or Step Previous Extended operation, is incorrect. The descriptor length (the first two bytes of the data buffer) on the extended operation call must be the exact length of the descriptor. This requirement does not apply to the data buffer length option, which can still be declared longer than necessary.
- On a Stat Extended operation, the signature field in the data buffer is not set to 0x74537845, the subfunction field is not set to 0x00000001, or the Pervasive.SQL Explorer field is not set to 0x00000000.
- On a Get Direct/Chunk or Update Chunk operation, the descriptor structure in the data buffer is incorrect, or is inconsistent either internally or with respect to the data buffer length.
- ActiveX control's buffers are not cleared and reallocated. Use the Init method to clear and reallocate the control's buffers before the use of any extended operations in the code. In addition, if you are using AutoMode, it is necessary to establish logical position (GetLast, GetFirst, GetEqual, etc.) before making the call to Init.
63: The data buffer parameter specified on an Insert Extended operation is invalid
An Insert Extended operation provided an invalid buffer. Either the buffer length is less than 5 bytes, or the number of records specified is 0. Correct the buffer length or the number of records.
64: The filter limit has been reached
The MicroKernel returns this status code for the following reasons:
- During a Get Next Extended, Get Previous Extended, Step Next Extended, or Step Previous Extended operation, a rejected record was reached; no other record can satisfy the given filtering condition, going in the direction that the operation specified. This is applicable only if the first segment of the key that the key number specified is also used as the first term of the filtering field.
- The number of records to be retrieved is greater than the number of records present in the file that satisfy the filter condition. This option is specified in the data buffer of the extended operation.
65: The field offset is incorrect
The field offset in the extractor of a Get Next Extended, Get Previous Extended, Step Next Extended, or Step Previous Extended operation is invalid based on the length of the retrieved record. Make sure that the field offset is a valid value (from 0 through the record length minus 1).
66: The maximum number of open databases has been exceeded
This status code is obsolete in Pervasive.SQL 2000i and later versions.
The MicroKernel tried to open files bound to too many MicroKernel databases. To avoid receiving this status code, you must set a higher value for the number of databases that the MicroKernel can open.
Refer to the Advanced Operations Guide for more information about bound files.
67: The MicroKernel cannot open the SQL data dictionary files
The MicroKernel returns this status code for the following reasons:
- An application attempted to use a data file that is bound to a the MicroKernel database, but the MicroKernel could not open one of the MicroKernel data dictionary files (FILE.DDF or, if the file has RI definitions, RELATE.DDF) or the configuration file (DBNAMES.CFG).
- You attempted to create a file with the Replace option, and a bound MicroKernel data file with the same name and location already exists. However, the MicroKernel could not open the MicroKernel data dictionary file FILE.DDF, or the configuration file (DBNAMES.CFG).
If the data file has RI definitions, the DBNAMES.CFG file must be in the location specified in the DBNames Configuration Location option in the server configuration settings. Also, ensure that FILE.DDF and RELATE.DDF (if the file has RI definitions) are in the locations specified by the Working Directory option in the server configuration settings.
68: The MicroKernel cannot perform the RI Delete Cascade operation
The MicroKernel cannot enforce the Delete Cascade rule on a file under RI control because the record that the application attempted to delete has more than 16 levels of descendants. Delete records from the lower levels, and then try again to delete the record that the application was attempting to delete initially. Refer to Advanced Operations Guide for more information about RI.
69: The Delete operation specified a file that is damaged
The application encountered an error while the MicroKernel was attempting to enforce the Delete Cascade rule in response to a Delete operation. This status code indicates that the related file has been damaged and must be recreated. Refer to Advanced Operations Guide for more information about RI and the Delete Cascade rule.
71: There is a violation of the RI definitions
- If you attempted an Insert operation on a file under RI control, a foreign key value in the record to be inserted does not have a corresponding primary key in the referenced file.
- If you are performing an Update operation, there are two possible causes for this status code:
- You attempted to change the value of a primary key.
- You attempted to change the value of a foreign key to a value that does not exist for the defined primary key.
- If you attempted a Delete operation, the restrict rule is enforced, and a primary key value in the record you are trying to delete references a foreign key in the referenced file. Refer to Advanced Operations Guide for more information about RI.
72: The MicroKernel cannot open the RI referenced file
The referenced file cannot be found at the location specified by FILE.DDF and DBNAMES.CFG. Be sure that the referenced file is in one of the data file locations that the DBNAMES.CFG file specifies for the named database.
- If the DBNAMES.CFG file is defined on a server, verify that the file location does not contain a drive letter.
- If the DBNAMES.CFG file is defined for a Workgroup engine, make sure that the drive letters are the same (and map to the same locations) as specified in DBNAMES.CFG.
Refer to Advanced Operations Guide for more information about RI.
73: The RI definition is out of sync
The MicroKernel returns this status code for the following reasons:
- You tried to open a data file that is bound to a MicroKernel database, and the database to which the file is bound was not found in the DBNAMES.CFG file.
- You tried to open a data file with RI (Referential Integrity) definitions that are bound to a MicroKernel database, and the table to which the file is bound was not found in the database FILE.DDF file, or the table location and filename do not match the file location and filename as configured in the DBNAMES.CFG or FILE.DDF file.
- You attempted to modify a bound file, and the RI definition for that file disagrees with the definition in the RELATE.DDF file.
- You attempted an Insert, Delete, or Update operation that would change a foreign key, if the file related to this file is out of sync (an attempt to open or modify the related file would have returned this same status code).
- You attempted to create a file with the Replace option, and a bound MicroKernel data file with the same name and location already exists. However, the MicroKernel detected that the existing bound file was out of sync (that is, an attempt to open the existing file would have returned this same status code).
Note
The same named database cannot exist on two servers on the same network. So, if the intent is to move the dictionaries to another server on the same network, one way would be to delete the named database on the old server before creating the same named database on the new server.
Check the RI constraints on your database. For information about how to do this, refer to Pervasive.SQL User's Guide.
74: The MicroKernel aborted the transaction
This status code is obsolete in MicroKernel versions 6.0 and later.
This is an informative status code. A NetWare-based MicroKernel replaced an End Transaction operation with an Abort Transaction operation after detecting an error for a Transaction Tracking System (TTS) file inside the transaction. The MicroKernel then executed the Abort Transaction operation.
76: There is a conflict on the referenced file
An application attempted to perform an Update, Insert, or Delete operation on an RI-controlled file that references another file. The application cannot open the referenced file for RI checking because it is already open in Exclusive mode. Wait until the referenced file is closed or is opened in a mode other than Exclusive, and then retry the operation. Refer to Advanced Operations Guide for more information about RI.
77: The application encountered a wait error
This status code is obsolete in MicroKernel versions 7.0 and later.
This is an informative status code. You must retry the operation yourself; the MicroKernel does not automatically retry the operation. A client/server MicroKernel returns this status code in one of the following situations:
- The application specified a wait lock bias for an operation, but another user has locked the requested resource.
- The application is currently processing a wait transaction and tried to access a file that another user has locked.
When you are using the Btrieve Requester to access the MicroKernel, the Requester waits and retries if a requested resource is locked. When a server-based application is accessing the MicroKernel and the requested resource is locked, a wait is also required. In this case, the MicroKernel is expected to perform the wait. Because this would occupy the MicroKernel and lock out other users who might be trying to release the requested resource, the MicroKernel does not perform the wait. Instead, it returns this status code, and the server-based application must retry later.
78: The MicroKernel detected a deadlock condition
The application should clear all resources by aborting, ending the transaction, or releasing all record locks before proceeding. This breaks the deadlock, allowing other applications to access the resources for which they are waiting.
79: A programming error occurred
This status code is obsolete in MicroKernel versions 7.0 and later.
There is a malfunction that the MicroKernel cannot specifically detect or from which the MicroKernel cannot recover. Retry the operation. If the error persists, there may be system corruption; try to clear the system by rebooting, and then try the operation again.
80: The MicroKernel encountered a record-level conflict
The MicroKernel did not perform the Update or Delete operation because of a record-level conflict. For example, station A reads a record, station B reads the same record and updates it, and then station A attempts to update the record. The application should reread the record prior to resending an Update or Delete operation. Alternatively, the application can employ record locks to avoid conflicts.
In key-only files, you receive this status code if the record is moved in the file b-tree after being read and before being updated or deleted. A record can move as a result of other records being inserted, updated, or deleted.
81: The MicroKernel encountered a lock error
The MicroKernel returns this status code in one of the following situations:
- The application tried to unlock a record that is locked with a multiple record lock, but the record position stored in the data buffer does not correspond to any record locked in the associated file.
- The application tried to unlock a single-record lock with a multiple-record lock or vice-versa.
82: The MicroKernel lost positioning
When performing a Get Next or Get Previous operation on a key with duplicates, the application tried to retrieve a record that was deleted or whose key value was modified by another application. Use a Get Equal or a Get Direct/Record operation to re-establish positioning. (See Status Code 44: The specified key path is invalid for a related positioning problem.)
83: The MicroKernel attempted to update or delete a record that was read outside the transaction
This status code is obsolete in MicroKernel versions 7.0 and later.
The application tried to update or delete a record within a transaction, but it did not read the record within the transaction. The application must read the record within the transaction before attempting to modify the data.
84: The record or page is locked
- An Insert, Update, or Delete operation attempted to lock an index page to insert or delete a key value. Have your application check for this status code and retry the operation if the status code is returned.
- When using a NetWare server engine, you can receive this status code when running an application on a Win95 client if the NetWare operating system runs out of record locks. To solve this, increase the "maximum record locks per connection" and, if necessary, the "maximum record locks" (system wide limit) on the NetWare server.
- The application tried one of the following:
- Applied a no-wait lock on a record that is currently locked by another application
- Tried to access a file in a no-wait transaction while another application holds one or more active record locks in that file
- Tried to update or delete a record locked by another application.
The application can use either of the following recovery methods:
- Retry the operation until it is successful. This can be the simplest and quickest solution for a network with light to moderate use.
Note
Applications should limit the number of retry attempts when status 84 is received inside a concurrent transaction. Otherwise, the application might enter a deadlock situation with another transaction. If status 84 is still received after a few retries, abort the transaction and then attempt the transaction again.
- Use the wait option (+100/+300) instead of the no-wait option (in versions that support the wait option).
85: The file is locked
The MicroKernel returns this status code in one of the following situations:
- The workstation MicroKernel has a file open, and client machine that has the Requester loaded tries to open the same file via the server MicroKernel. The server MicroKernel cannot open the file because it cannot obtain exclusive access. The client machine that has the Requester loaded receives this status code.
- While one user has a file locked in an exclusive transaction, another user attempts to lock all or part of that file.
- When opened by a MicroKernel, a file is in transition into Continuous Operation mode. Retrying eventually works.
- When opened by a MicroKernel, two data files have the same filename but different extensions (for example, INVOICE.HDR and INVOICE.DET). One file is open and in Continuous Operation mode, causing the MicroKernel to generate a delta file (for example, INVOICE.^^^). The MicroKernel returns this status code when you attempt to open the second file. For this reason, we recommend naming your files with completely different names, not just reusing the same name with different extensions.
- When opened by a Windows server MicroKernel using Microsoft File and Print Services for NetWare on behalf of a Win16 Windows client, the file was also opened simultaneously by a Windows 32-bit or Windows 98/ME machine. This causes the server MicroKernel to open the same physical file using two different paths.
- Without any pattern of occurrence, you may receive a status 85 when the file is closed because Anti-Virus software opens and locks the file to scan causing the next database operation to fail. To resolve, set the Anti-Virus software to not scan Pervasive SQL data files. Consult your Anti-Virus software manual for instructions on how to exclude files.
86: The file table is full
This status code is obsolete in the current version of Pervasive.SQL. The engine now dynamically manages the number of files that the MicroKernel can open.
87: The handle table is full
This status code is obsolete in Pervasive.SQL 2000i and later versions. The handle table is managed dynamically by the engine.
You have either attempted to open more handles than the MicroKernel is configured to support, or the MicroKernel attempted to open more files than the operating system allows.
- To configure your operating system to allow more handles, refer to your operating system documentation.
It is helpful to know the following details regarding the MicroKernel requirements for handles from the operating system. When the same file is opened multiple times, the MicroKernel uses only one operating system handle. However, if the file is in v6.x or later format and the file is shared via MEFS mode, the MicroKernel opens a second handle for the associated .LCK file.
If the file is in v5.x format, the MicroKernel might request a second handle, for the .PRE file. Also, if the file (in any format) is placed in Continuous Operation mode, the MicroKernel requests another handle for the delta file. If the file is extended, the MicroKernel requests an operating system handle for each of the extension files.
- In the Btrieve v6.15 DOS or Microsoft Windows NT 4.0 environments, you may received this status code when opening the 16th file in a DOS application running under Windows NT. There may two solutions:
- Btrieve File handle configuration may be set incorrectly in BTI.CFG. Check BTI.CFG for file handle setting (/h: and /f:) and increase those values.
- Check the file= setting in CONFIG.NT. This file is in the WINNT\SYSTEM32 directory and raise the values.
NOTE: default value is 20.
88: The application encountered an incompatible mode error
The MicroKernel returns this status code in one of the following situations:
- If an application opens a file in Exclusive mode, all other applications receive this status code when they try to open the same file in any mode.
- If an application opens a file in any mode other than Exclusive, all other applications receive this status code when they try to open the same file in Exclusive mode.
- While using the MicroKernel Continuous Operation mode:
- You attempted to remove a file from continuous operation, but the file is not in continuous operation mode.
- You attempted to remove a file from continuous operation, but a different client placed the file into continuous operation.
- You attempted to include two files in continuous operation that have the same name but different extensions.
- You attempted to include a file in continuous operation, but the file is already in continuous operation.
- The files were previously in continuous operation and the server crashed. Now, when you attempt to take the files out of continuous operation, a Status Code 88 is returned.
In the last case described above, once the server has gone down, the Btrieve engine does not know which files were in continuous operation. Status Code 88 is returned because of this condition.
In order for you to take the files out of continuous operation, you must open the files before trying to end continuous operation mode. When the file is reopened, the Btrieve engine detects that the continuous ops flag is set and looks for the delta file. At that point, the delta file roll-in occurs.
To initiate the roll-in of an existing delta file, the associated data file must be opened. You can open the file with a utility such as the function executor or the application that uses the file. If the application that uses the file repeatedly opens and closes the file, you are advised to open the file with the function executor. This recommendation is made because the delta roll-in is a low priority task. The roll-in was designed in this fashion so that the file can still be used while the roll-in is occurring. If the application closes the file and the roll-in has not finished, the roll-in is initiated again when the file is re-opened. As a low priority task, the roll-in process may take some time. Once the engine completes the roll-in, it deletes the delta file.
89: A name error occurred
This status code is obsolete in MicroKernel versions 5.0 and later.
BSERVER was loaded before you specified the short name to which the device was redirected. You must specify all short names that you want to share with the NET SHARE command before you start BSERVER.
90: The redirected device table is full
This status code is obsolete in MicroKernel versions 6.0 and later.
The DOS Requester redirection table or server routing table is full. This occurs if you attach to additional servers or map additional drives after loading the Requester. Reload the Requester, specifying a larger value for either the Number of File Servers (/S) option or the Number of Mapped Drives (/R) option. This status code also occurs if you detach from a server and attach to a different server. Once a client has attached to a server, the Requester does not remove its name from the server routing table.
For a list of all available BRequest commands, type /? at the command line.
91: The application encountered a server error
Note
Please see our Pervasive.SQL Knowledge Base for new and updated articles on troubleshooting this status code. You can access the Knowledge Base at: http://support.pervasive.com/eSupport/.
The MicroKernel returns this status code in one of the following situations:
- The Requester cannot establish a session with the server. Either the client/server MicroKernel is not loaded or the server is not active.
- The SPX drivers are not installed or are outdated.
- The MicroKernel has reached the maximum limit for the number of sessions it can open at one time. To avoid receiving this status code, increase the value for the Number of Sessions configuration option. Beginning with Pervasive.SQL 8, the MicroKernel dynamically manages the number of sessions, and it cannot be manually increased or decreased.
- An application specified a path for a file and did not include the volume name in the path.
- The MicroKernel Router has not been loaded, and the following situation has occurred: an application that uses both the MicroKernel Router and the MicroKernel to make remote calls (and which therefore includes the server and volume name when performing an Open operation) has attempted to open a remote file. Because the MicroKernel Router does not interpret the server name, the MicroKernel attempts to do so but cannot.
- A communication or network addressing problem exists in your network environment, so the MicroKernel requests never reach their destination server address. Ensure that your client and server network components are up to date and certified for your network environment.
- There is a conflict using the DOS BREQNT requester with the SPX protocol. To resolve this error:
- Change directories to
\pvsw\clients\dos\windosbox and run the setup utility. This loads the appropriate file for clients running Windows 98/ME or Windows 32-bit platforms. The setup program creates and places a README.TXT file in the \pvsw\W32DOXBOX directory.
- After installation, reboot the client.
- For Windows 32-bit platform users: open a command prompt and run a DOS Btrieve application.
- For Windows 98/ME users:
- Run the BTRBOX95.exe. A minimized dialog box appears, indicating that BTRBOX95 support is active. If you close this dialog box, it will unload BTRBOX95. You only need to run BTRBOX95.exe once even though you have multiple DOS sessions open.
- Open a command prompt and run your DOS Btrieve application.
- For NetWare servers only:
- The Receive Packet Size configuration option is inappropriate for your environment. For example, the setting should be 1500 for an Ethernet LAN or 4096 for a Token-Ring LAN.
To adjust the Receive Packet Size:
- Click Communication Buffer Size in the properties tree.
- Ensure that the Receive Packet Size value is appropriate for your environment.
NetWare users may also receive this status code in the following situations:
- The user count limit has been exceeded. Either close a session or upgrade your user count. For more information about purchasing and installing additive user counts, refer to Pervasive.SQL User's Guide.
- Ensure that the NDS network number is the same as the Internal Network Number viewed by BINDER.EXE output.
- You ran BUTIL.NLM to roll forward a file using a log filename other than the default, and your BLOG.CFG file did not contain a correct entry such as "\dir\file.ext=vol:\dir\log.ext".
92: The transaction table is full
This status code is obsolete in MicroKernel versions 7.0 and later.
The application exceeded the maximum number of active transactions. Use the configuration properties to specify a higher value for the Number of Transactions configuration option.
93: The record lock types are incompatible
The application tried to mix single-record locks (+100/+200) and multiple-record locks (+300/+400) in the same file at the same time. You must release all locks of one type before you can execute a lock of the other type.
94: The application encountered a permission error
The MicroKernel returns this status code in the following situations:
- The application tried to open or create a file in a directory without the proper privileges. The MicroKernel does not override the network privileges assigned to users.
- The designated server is in the server routing table, but your particular client is not logged into that server.
- The system data source name (DSN) on the server has an error in the pathname to the data files.
- A NetWare application tried to access a file using NetWare Runtime support with the given username. Specifically, one of the following situations exists regarding the supplied username:
- The user is not a valid user on the NetWare Runtime server.
- The user does not have the appropriate rights to access the file.
- The username is ADMIN or SUPERVISOR. For security reasons, the MicroKernel does not enable you to use ADMIN or SUPERVISOR as a username when enabling NetWare Runtime support.
- User is logged in to NetWare server with grace login (i.e., password has expired and a set number of grace logins are left). Change the user's password to a valid password (no grace login) and reconnect to the server with the valid password.
- When using the Win32 Requester from a Windows 32-bit or a 98/ME client machine to a NetWare server, you must use the same username for logging in to both the client machine and the NetWare server. You cannot be logged in to NetWare as SUPERVISOR or ADMINISTRATOR.
- When using the Win32 Requester from a Windows 32-bit or a 98/ME client machine using NetWare emulation to a Windows NT server, the server cannot use Microsoft File and Print Services for NetWare. This causes the requester to attempt authentication as though the server were a NetWare Runtime server.
- It is recommended that you keep the default client configuration setting Access4Use Remote MicroKernel Engine = Yes on FPNW servers running Pervasive.SQL. You may receive a Status Code 94 if you change this setting to No when you are running the Btrieve Interface locally on the FPNW server and are using a local FPNW drive mapping or local FPNW UNC path.
- You may also receive this status if you have Client for NetWare Networks installed on a Windows only network where no NetWare servers present. Remove the Client for NetWare Networks from the Windows 95 workstation.
95: The session is no longer valid
Note
Please see our Pervasive.SQL Knowledge Base for new and updated articles on troubleshooting this status code. You can access the Knowledge Base at: http://support.pervasive.com/eSupport/.
The server MicroKernel returns this status code for one of the following reasons:
- The previously established session is no longer active due to an error at the client machine, at the server, or on the network. Verify that the client machine is still attached to the server, and then unload and reload the Btrieve Requester.
If you are using the SPX protocol:
- The server MicroKernel has reached the maximum number of SPX sessions. Use the Monitor utility to check this statistic. To avoid receiving this status code, add more memory. The number of sessions is managed dynamically up to available memory.
- This may be a time delay problem if the client machine does not receive a response back from the server in an appropriate time frame or after an appropriate number of retries. Refer to your network configuration documentation for information about increasing timeout and retry parameters. This is often necessary in a WAN environment or a LAN configuration with heavy network traffic.
- For NetWare servers:
- Verify that the Receive Packet Size configuration option is appropriate for your environment. For example, the setting should be 1500 for an Ethernet LAN.
To adjust the Receive Packet Size:
- Click Communication Buffer Size in the properties tree.
- Ensure that the Receive Packet Size value is appropriate for your environment.
- Ensure that the SPX timeout parameters are set as follows in both the client machine NET.CFG file and the server SPXCONFG.NLM file:
SPX VERIFY TIMEOUT=54
SPX LISTEN TIMEOUT=108
SPX ABORT TIMEOUT=540
These three values must have a 1:2:10 ratio. You can increase these values to at most three times the default. If you continue to receive this status code after increasing these values, the problem is most likely not related to these settings.
- For Windows servers, verify that the Maximum Packet Size registry setting is 576 decimal or 240h. The path to the MaxPktSize registry setting is
HKEY_LOCAL_MACHINE\System\currentControlSet\
Services\NwInkIPX\NetConfig\MaxPktSize.
If you continue to receive this status code after increasing the network timeout parameters, this status code usually indicates a problem with network communications. Verify that you have up to date network cards and drivers; for example, incompatible LAN card drivers can also cause this status code to occur. Consult your LAN administrator for network communication troubleshooting.
- After installing Windows NT Service Pack 3 or 4, SPX requesters may fail and return this status code (95), Status 97, or Status 91. Refer to the Microsoft Knowledgebase article 170517 for more information regarding this cause.
- Choose Start4Run.
- Type Regedit and click OK. The Registry Editor opens.
- Make the following CHANGES to the server's registry using Regedit:
HKEY_Local_Machine4System4CurrentControlSet4Services4NwLnkIpx4<Network Card>4MaxPktSize = 240 Hex.
HKEY_Local_Machine4System4CurrentControlSet |
Services4NwLnkIpx4<Network Card>4NetworkNumber = <Non-Zero Value>
- ADD the following registry entry:
HKEY_Local_Machine4System4CurrentControlSet |
Services4LanManServer4Parameters4MinClientBufferSize regdword = 500 decimal.
96: A communications environment error occurred
The MicroKernel returns this status code for the following reasons:
- You tried to attach to the MicroKernel on a server, but the SPX connection table or the MicroKernel client table is full. To avoid receiving this error, add more memory. Both of these resources are managed dynamically up to available memory.
- An application that calls the MicroKernel can return this status code if the DBNAMES.CFG file contains a named database definition specifying a data location on a different server.
- You may also receive this status code in an environment with multiple servers with Btrieve running on them. When doing a Begin Transaction using BREQUEST 6.15, the requester checks its list of all known attached Btrieve file servers. Then it attempts to create an SPX session so that it can check the server to see if it is configured for transactions. This implies that all the servers have to be configured for at least the same number of remote sessions as well as being configured for the same number of transactions.
97: The data buffer is too small
The application either tried to read or write a record that is longer than the current allowed settings for the MicroKernel or the Btrieve Requester, as follows:
- For an Update, Insert, or Create operation, the application receives this status code if the data buffer length it specifies for the record exceeds the message buffer length.
- For a Get, Step, or Stat operation, the application receives this status code if the message buffer is shorter than the length of the data the MicroKernel would return, regardless of the data buffer length specified in the application.
- For a Get Chunk or Update Chunk operation, the total size of the retrieved or updated chunk exceeds the message buffer length.
- DOS Requesters only: Reload the Btrieve Requester and specify a higher value for the message buffer size. This is done using the
/D parameter which is documented in Getting Started with Pervasive.SQL.
- For Windows servers, verify that